TS Series III


Features

  • Highest power density on the market: Starting at 15 kW in a 3U package
  • 80 Models: 16 to 1000 Vdc, 20 to 2700 Adc
  • 15 kW models available for rental.
  • Wide range of input voltage: From 208 Vac to 480 Vac, at 50 Hz, 60 Hz, and 400 Hz
  • Optically isolated user I/O circuitry standard: No additional isolation circuitry necessary
  • Front panel analog potentiometers: Stepless rotary control
  • RS-232 interface standard with SCPI Commands: GPIB, USB, LXI TCP/IP Ethernet, RS-485 interfaces optional
  • LXI TCP/IP ethernet communications: Embedded web-server
  • OVT and OCT shutdown standard: Mechanical contactors to disconnect input mains
  • Programmable output modulation: With D Panel, emulates user-defined power profiles & New Photovoltaic Power Profile Emulation software
  • Certified LabWindows/CVI and LabView Drivers: GPIB, RS232, and LXI TCP/IP Ethernet
  • Load dependent air or optional water cooling
  • High power factor
  • CE Mark CE Mark

 

 

Specifications

 

Input
Nominal Voltage
3 phase, 3 wire + ground
208 VAC (operating range 187 - 229 VAC)
240 VAC (operating range 216 - 264 VAC)
380 VAC (operating range 342 - 418 VAC)
415 VAC (operating range 373 - 456 VAC)
440 VAC (operating range 396 - 484 VAC)
480 VAC (operating range 432 - 528 VAC)
1 phase, 2 wire + ground 208 VAC (operating range 187 - 229 VAC)
240 VAC (operating range 216 - 264 VAC)
Frequency 50 through 400 Hz
Power Factor Greater than 92% at maximum power
 
Environmental
Operating Temperature 0°C to 50°C
Storage Temperature -25°C to +85°C
Air Cooling Side air inlet, rear exhaust
Water Cooling (Optional) 25°C maximum inlet temperature
1.5 GPM minimum flow rate for 15 kW units
3.0 GPM minimum flow rate for 20-30 kW units
4.5 GPM minimum flow rate for 45 kW units
80 PSI maximum pressure
1/4” NPT female pipe size
 
Physical
Dimensions
(H" x W" x D")
15 kW: 5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm)
20 kW: 10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm)
25 kW: 10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm)
30 kW: 10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm)
45 kW: 15¾" x 24" x 19" (40.01 x 60.96 x 48.26 cm)
Weight 15 kW: 125 lbs (56.70 kg)
20 kW: 195 lbs (88.45 kg)
25 kW: 220 lbs (99.79 kg)
30 kW: 245 lbs (111.13 kg)
45 kW: 365 lbs (165.56 kg)
 
Output
Ripple See Model Charts
Line Regulation Voltage Mode: ± 0.004% of full scale
Current Mode: ± 0.02% of full scale
Load Regulation Voltage Mode: ± 0.01% of full scale
Current Mode: ± 0.04% of full scale
Load Transient Response 2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change
Efficiency ≥ 86%
Stability ± 0.10% for 8 hrs. after 30 min. warmup
Isolation Maximum input voltage to ground: ±2500 Vac
User inputs and outputs: referenced to Earth ground

For models less than or equal to 1000 Vdc:
Maximum output voltage to ground: ±1000 Vdc

For models greater than 1000 Vdc:
Maximum output voltage to ground: ±4000 Vdc
 
Programming Levels and Accuracy of Full Scale
Voltage
Set Point
Current
Set Point
OVT
Set Point
OCT
Set Point
Remote Analog Programming Accuracy ± 0.50% ± 0.75% ± 0.50% ± 0.75%
Digital Programming Accuracy ± 0.50% ± 0.75% ± 0.50% ± 0.75%
Remote Analog Programming Levels 0 - 10.0 Vdc 0 - 10.0 Vdc 0 - 11.0 Vdc 0 - 11.0 Vdc
 
Monitoring Levels and Accuracy of Full Scale
Output Voltage Output Current
Remote Analog Monitoring Accuracy ± 0.50% ± 0.75%
Digital Monitoring Accuracy ± 0.50% ± 0.75%
Remote Analog Monitoring Levels 0 - 10.0 V 0 - 10.0 V
 
Control Limits
Remote Sense Limits 3% maximum voltage drop from output to load
Period Programming Limits Minimum period: 10 msec
Maximum Period: 9997 sec or 2.77 hours
Digital control inputs and outputs limits Input voltage: 0 to 10 Vdc
Output voltage: 0 to 10 Vdc, 5 mA drive capacity